Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Braz. dent. j ; 32(6): 36-53, Nov.-Dec. 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1355845

RESUMO

Abstract The aim of this study was to evaluate the survival of laminate veneers constructed using a recent polymer-infiltrated ceramic network material following the aesthetic pre-evaluative temporary (APT) technique of tooth preparation in comparison to traditional technique. Six patients received 54 laminate veneers. They were divided into two equal groups (n=27) according to the technique of tooth preparation: group T: traditional technique and group A: aesthetic pre-evaluative temporary technique. VITA ENAMIC material was used for CAD/CAM construction of laminate veneers. Cementation was performed using a light cured resin cement. The laminate veneers were evaluated at baseline, after 3, 6 and 12 months according to the modified United States Public Health Service (USPHS) criteriea. The data was collected, tabulated and statistically analyzed. Secondary caries, endodontic complications, cracks and loss of retention were not noted in any laminate veneer. Extensive fractures were not detected in both study groups through the study period. There was a statistically significant decrease of color match criteria between the two groups at the 6 and 12 months recalls. Based on this study, both preparation techniques resulted in successful clinical performance. After 12 months, all the veneers in both groups showed no post-operative sensitivity and all patients were highly satisfied regarding their veneers. However, there was a deterioration in color match criteria through the study period in both study groups.


Resumo O objetivo deste estudo foi avaliar a sobrevivência de facetas laminadas construídas utilizando um material recente de rede de cerâmica impregnada de polímero, seguindo a técnica estética pré-avaliadora temporária (APT) de preparação de dentes em comparação com a técnica tradicional. Seis pacientes receberam 54 facetas de laminados. Foram divididos em dois grupos iguais (n=27) de acordo com a técnica de preparação do dente: grupo T: técnica tradicional e grupo A: técnica temporária pré-avaliativa estética. O material VITA ENAMIC foi utilizado para a construção de facetas de CAD/CAM de laminados. A cimentação foi realizada utilizando um cimento de resina fotopolimerizável. Os laminados foram avaliados na linha de base, após 3, 6 e 12 meses de acordo com os critérios modificados do Serviço de Saúde Pública dos Estados Unidos (USPHS). Os dados foram recolhidos, tabulados e analisados estatisticamente. Cáries secundárias, complicações endodônticas, fissuras e perda de retenção não foram observadas em nenhuma faceta laminada. Não foram detectadas fraturas extensas em ambos os grupos de estudo durante o período do estudo. Verificou-se uma diminuição estatisticamente significativa dos critérios de correspondência de cor entre os dois grupos nos 6 e 12 meses. Com base neste estudo, ambas as técnicas de preparação resultaram num desempenho clínico bem sucedido. Após 12 meses, todos os laminados de ambos os grupos não mostraram qualquer sensibilidade pós-operatória e todos os pacientes ficaram altamente satisfeitos com os seus laminados. No entanto, houve uma deterioração dos critérios de correspondência de cor durante o período de estudo em ambos os grupos de estudo.

2.
Braz Dent J ; 32(6): 36-53, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35019018

RESUMO

The aim of this study was to evaluate the survival of laminate veneers constructed using a recent polymer-infiltrated ceramic network material following the aesthetic pre-evaluative temporary (APT) technique of tooth preparation in comparison to traditional technique. Six patients received 54 laminate veneers. They were divided into two equal groups (n=27) according to the technique of tooth preparation: group T: traditional technique and group A: aesthetic pre-evaluative temporary technique. VITA ENAMIC material was used for CAD/CAM construction of laminate veneers. Cementation was performed using a light cured resin cement. The laminate veneers were evaluated at baseline, after 3, 6 and 12 months according to the modified United States Public Health Service (USPHS) criteriea. The data was collected, tabulated and statistically analyzed. Secondary caries, endodontic complications, cracks and loss of retention were not noted in any laminate veneer. Extensive fractures were not detected in both study groups through the study period. There was a statistically significant decrease of color match criteria between the two groups at the 6 and 12 months recalls. Based on this study, both preparation techniques resulted in successful clinical performance. After 12 months, all the veneers in both groups showed no post-operative sensitivity and all patients were highly satisfied regarding their veneers. However, there was a deterioration in color match criteria through the study period in both study groups.


Assuntos
Porcelana Dentária , Facetas Dentárias , Cimentação , Cerâmica , Humanos , Cimentos de Resina , Preparo do Dente
3.
Braz. dent. sci ; 23(2): 1-10, 2020. ilus, tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1095378

RESUMO

Objective: The purpose of the study was to evaluate the effect of different preparation designs and different surface treatments on the fracture resistance of monolithic zirconia inlay-retained fixed dental prosthesis [IRFDP]. Material and methods: Forty-five translucent zirconia IRFDPs were divided into three groups according to preparation designs (n = 15); group I: proximal box, group II: inlay-box and group III: butterfly wing (modified inlay). Each group was further subdivided into three subgroups according to the surface treatments utilized (n = 5); sandblasting, tribochemical silica coating (Cojet system) and erbium, chromium: Yttrium, scandium, gallium, garnet (Er, Cr: YSGG) laser irradiation. All zirconia IRFDPs were cemented to their respective resin models using selfadhesive resin cement. All cemented IRFDPs were subjected to fracture resistance test using universal testing machine. The initial fracture site was determined by using a stereomicroscope (x6.7magnification). Two-way analysis of variance (ANOVA) was used to evaluate the effect of different designs, different surface treatments and their interaction on the mean fracture resistance. Bonferroni's post-hoc test was used when ANOVA is significant (P ≤ 0.05). Results: Butterfly wings design showed the highest fracture resistance values followed by inlay and box designs respectively (P ≤ 0.05). Sandblasting and Cojet showed significantly the highest mean fracture resistance values than Laser with no significance difference between them. Conclusion: The butterfly wing design increased the fracture resistance of the zirconia IRFDPs. Sandblasting and tribochemical silica coating of zirconia surfaces had a greater effect than Er, Cr: YSGG laser to gain higher fracture resistance of zirconia IRRDPs (AU)


Objetivo: O objetivo do estudo foi avaliar o efeito de diferentes modelos de preparações e diferentes tratamentos de superfície na resistência à fratura de inlays de zircônia monolítica. Material e métodos: Quarenta e cinco inlays translúcidos de zircônia foram divididos em três grupos de acordo com os desenhos de preparação (n = 15); grupo I: caixa proximal, grupo II: inlay convencional e grupo III: asa de borboleta (inlay modificado). Cada grupo foi subdividido em três subgrupos de acordo com os tratamentos de superfície utilizados (n = 5); jateamento de areia, revestimento triboquímico de sílica (sistema Cojet) e érbio, cromo: ítrio, escândio, gálio, granada (Er, Cr: YSGG) irradiação a laser. Todos os inlays de zircônia foram cimentados em seus respectivos modelos de resina usando cimento de resina auto-adesivo. Todos os inlays cimentados foram submetidos a teste de resistência à fratura usando máquina de teste universal. O local inicial da fratura foi determinado usando um estereomicroscópio (ampliação de 6,7x). A análise de variância (ANOVA) de dois fatores foi usada para avaliar o efeito de diferentes desenhos, diferentes tratamentos de superfície e sua interação na resistência média à fratura. O teste post-hoc de Bonferroni foi usado quando a ANOVA foi significativa (P ≤ 0,05). Resultados: O design das asas de borboleta apresentou os maiores valores de resistência à fratura, seguidos pelos designs de inlay convencional e caixa, respectivamente (P ≤ 0,05). O jateamento de areia e o Cojet apresentaram significativamente os maiores valores médios de resistência à fratura do que o Laser, sem diferença de significânc=ia entre eles. Conclusão: O design da asa de borboleta aumentou a resistência à fratura dos inlays de zircônia. O revestimento por jato de areia e triboquímica de sílica das superfícies de zircônia teve um efeito maior que o laser Er, Cr: YSGG para obter maior resistência à fratura dos inlays de zircônia. (AU)


Assuntos
Ensaios Clínicos Adaptados como Assunto , Resistência à Flexão , Restaurações Intracoronárias
4.
J Oral Implantol ; 39(4): 417-24, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23964776

RESUMO

This study evaluated the effect of fabrication techniques and cyclic loading on the vertical marginal fit of implant-supported fixed partial denture (FPD) frameworks. Thirty implant-supported 3-unit FPD frameworks were fabricated on a model system, divided into 3 equal groups (n = 10). The first group (control) was constructed from base metal alloy; the other 2 test groups were constructed from all-ceramic zirconia using a computer-aided design/computer-aided manufacturing (CAD/CAM) Cerec 3 system and a copy milling (Zirkonzahn) system. A cyclic load of 200 N was applied to each framework for up to 50,000 cycles. Linear measurements were made in micrometers of the vertical gap between the framework and the implant-supported abutment at 16 predetermined points before and after cyclic loading. The frameworks were viewed using scanning electron microscopy to inspect any fractographic features. One-way analysis of variance was performed to compare the marginal discrepancy values of the control and the 2 test groups and for each group; a t test was applied to determine whether significant changes in the fit were observed after cyclic loading (α = 0.05). The CAD/CAM group showed significantly higher marginal gap mean values (80.58 µm) than the Zirkonzahn and control groups (50.33 µm and 42.27 µm, respectively) with no significant difference. After cyclic loading, the CAD/CAM group recorded the highest marginal gap mean value (91.50 ± 4.260 µm) followed by control group (72.00 ± 2.795 µm); the Zirkonzahn group recorded the lowest marginal gap (65.37 ± 6.138 µm). Cyclic loading significantly increased the marginal gap mean values in the control group only. A marginal chip was observed in one of the CAD/CAM ceramic frameworks. Within the limitations of this study, the fabrication technique influenced the marginal fit of the implant-supported 3-unit FPD frameworks. Cyclic loading failed to change the fit of all-ceramic zirconia frameworks, whereas significant changes were found in the metal frameworks.


Assuntos
Adaptação Marginal Dentária , Porcelana Dentária , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Prótese Parcial Fixa , Zircônio , Análise de Variância , Desenho Assistido por Computador , Ligas Dentárias , Análise do Estresse Dentário , Humanos , Microscopia Eletrônica de Varredura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...